New Single-Family Home Building Permit Submittal Requirements

This section describes the minimum submittal requirements for new single-family homes and new single-family homes with an attached ADUs. All work must be designed to meet the minimum requirements of the California Building Standards Code and local amendments in effect at the time of permit application, Planning and Engineering Division requirements and the City of Menlo Park’s Municipal Code.

The City of Menlo Park only accepts on-line digital Building permit applications with digital plans and supporting documents. All applications, plans and supporting documents are to be submitted digitally through the City’s Accela permit management system using  the Accela Citizen Access Portal (ACA). Please visit the Building Division’s Online service web page for information associated with how to register for an ACA account. The digital file specifications for all plans can be found on the Online services page under File specifications.

Applicants are encouraged to have plans drawn by a professional architect or designer familiar with Menlo Park’s building permit process. This will facilitate a timely review of the project plans.  If the owner wishes to complete the plans on his/her own, please contact City staff to ensure that all information is prepared properly. It is to the applicant’s advantage to submit legible and clear plans. Plans that cannot be read or understood will not be accepted. This may result in a delay of the plan review process and may cause additional costs to the applicant.

If a project has received a discretionary approval, the applicant is strongly encouraged to also submit a copy of written documentation demonstrating compliance with all of the conditions associated with the project.

The plans are to show compliance with the Federal Emergency Management Agency (FEMA) requirements and Chapter 12.42 Flood Damage Prevention of the City's Municipal Code if the project is located in Flood Zones A, AE, AH or AO. Please see Floodplain construction for detailed requirements.

Menlo Park Fire Protection and West Bay Sanitary Districts

The Menlo Park Fire Protection District (MPFPD) and West Bay sanitary District (WBSD) are separate and independent agencies from the City of Menlo Park. Depending on the scope of work for proposed project, both MPFPD and WBSD may require a permit, plan review and inspection. It is important to note that:

  • It is the responsibility of the applicant or applicant’s representative to coordinate the permit submittal, plan review, approval and inspection for Fire Code and sanitary sewer related work with the MPFPD and WBSD.
  • It is the responsibility of the applicant or applicant’s representative to upload approval documents into the Accela Citizen Access Portal (ACA).
  • A Building permit from the City of Menlo Park will not be issued until both the MPFPD and WBSD have approved the project if a permit is required.

Contact the MPFPD directly at www.menlofire.org or 650-688-8400 regarding any permitting questions or requirements.

Contact the WBSD directly at info@westbaysanitary.org or 650-321-0384 regarding any permitting questions or requirements.

Permit Application Submittal Requirements

Please refer to Documents associated with a complete plan submittal for a complete description of the required submittal documents listed below.

Plan Set Requirements

  1. Site Plan 

  2. Boundary and Topographic Survey - Please see Boundary and Topographic Survey Requirement Criteria(PDF, 158KB) and Boundary and Topographic Survey Requirements(PDF, 261KB)

  3. Floor Area and Building Coverage Plan

  4. Floor Plan(s)

  5. Roof Plan

  6. Exterior Elevations

  7. Building Sections

  8. Mechanical Plan

  9. Electrical Plan -  including an electrical one-line drawing

  10. Plumbing Plan

  11. Structural Plan - including Foundation, floor framing, roof framing and structural details.

  12.  Title 24 Energy Code Calculations

  13. Civil Plans - Please see Single-family home projects for detailed requirements. 

  14. Construction Safety Fence plan - Minimum six foot (6-ft.) tail chain link fence around the site. An existing wood fence can be used in lieu of the chain link fence.

Required Supporting Documents

  1. Building Permit Application Form(PDF, 174KB)
  2. Completed Menlo Park data sheet for building permit application
  3. Completed Checklist For Engineering Submittals with Building Permit Applications -Please see Single-family home projects for detailed requirements.
  4. Completed Deferred Submittal Form
  5. Geologist report
  6. Structural Calculations
  7. Electric Load Calculations(PDF, 1MB) - this may be included in the plan set
  8. Completed Impervious Area Worksheet -Please see Single-family home projects for detailed requirements.
  9. An arborist report will be required if there are heritage trees in the vicinity of the proposed construction - Please see Trees for heritage tree definitions and requirements.

  

Contact us

Building permits and general questions
650-330-6704
Email 

Inspection questions
Schedule online or 650-330-6767

Alternate Fridays closed